Fuel return line

Discussion in 'Technical' started by boss9, Jun 22, 2006.

  1. boss9

    boss9 Member

    Joined:
    Nov 14, 2005
    Messages:
    569
    Likes Received:
    0
    Trophy Points:
    0
    Location:
    Akron,Ohio
    Vehicle:
    77 4-door 250 I6
    I need to install a fuel return line on my gas tank. I was looking under the hood and on the firewall on the passenger side is a line with a rubber plug on the end of it. I haven`t investigated but it appears to be a vent line that may have gone into a smog canister. If that`s the case, could that be used as a return line ?
    Thanks, Darrel
     
  2. Mavaholic

    Mavaholic Growing older but not up!

    Joined:
    Mar 9, 2002
    Messages:
    14,992
    Likes Received:
    209
    Trophy Points:
    258
    Location:
    Live Oak, FL
    Vehicle:
    Original 72 Sprint Owner, 71 Comet GT, 57 Ranchwagon, 57 4 dr Wagon
    There is a check valve on top of the tank which that line goes to. You would have to modify it or eliminate it so fuel could flow back into the tank.
     
  3. MavMark

    MavMark Mega Modifier

    Joined:
    Mar 10, 2002
    Messages:
    779
    Likes Received:
    13
    Trophy Points:
    117
    Location:
    Detroit Area, Michigan
    Vehicle:
    1972 Grabber, 351w,EFI,A/C, RRS Rack, Power Everything :)
    You can indeed use that as a return line...I am doing just that on my '72. I know the '77 line is a little smaller, so it may raise fuel pressure. Mavaholic is right...you will need to drop the tank and take the valve at the top of the tank apart. On my '72 there was no check valve per se...but the hole was very small. I originally didn't do this and everything seemed fine...then one day some dirt or something clogged the hole and my fuel pressure spiked to about 100 PSI :eek: I burst the rubber part of the line under the car..and then had lots of black smoke from the exhaust (and about 2 mpg) for a bit before I figured out what happened, dropped the tank and enlarged the hole...

    Anyway..yeah, it can be done. :)
     
  4. boss9

    boss9 Member

    Joined:
    Nov 14, 2005
    Messages:
    569
    Likes Received:
    0
    Trophy Points:
    0
    Location:
    Akron,Ohio
    Vehicle:
    77 4-door 250 I6
    Thanks for the replies guys. (y) One of my other options is to cut out a 2" section of my filler tube and install a pre-made return neck from Summit. I'm hoping I don't have to do that, but the fuel regulator requires a return.
     
    Last edited: Jun 23, 2006
  5. don graham

    don graham MCG State Rep

    Joined:
    Mar 10, 2002
    Messages:
    15,800
    Likes Received:
    16
    Trophy Points:
    302
    Location:
    arizona city, az.
    Vehicle:
    70 mav, 71 grabber, 73 Comet, 2004 f-250 crew cab diesel, 2001 f-250, 2004 explorer, 2007 Gold Wing trike.
    what fuel pump are you using. is this for gas?
     
  6. boss9

    boss9 Member

    Joined:
    Nov 14, 2005
    Messages:
    569
    Likes Received:
    0
    Trophy Points:
    0
    Location:
    Akron,Ohio
    Vehicle:
    77 4-door 250 I6
    The fuel pump is a Holley red with a Mallory 4309 boost referenced regulator. :D
     
  7. don graham

    don graham MCG State Rep

    Joined:
    Mar 10, 2002
    Messages:
    15,800
    Likes Received:
    16
    Trophy Points:
    302
    Location:
    arizona city, az.
    Vehicle:
    70 mav, 71 grabber, 73 Comet, 2004 f-250 crew cab diesel, 2001 f-250, 2004 explorer, 2007 Gold Wing trike.
    what are you building that needs a return line to the gas tank. the holley red is a standard pressure pump preset at 7pounds and needs no regulator or return line as far as i know. which probably isn't too far. i'm confused (easily done, just ask my wife). the mallory 4309 is adjustable from 3-12 pounds but your pump won't put out more than 7 max. do you need less pressure? i'm curious. guess that's how i learn. :huh:
     
  8. boss9

    boss9 Member

    Joined:
    Nov 14, 2005
    Messages:
    569
    Likes Received:
    0
    Trophy Points:
    0
    Location:
    Akron,Ohio
    Vehicle:
    77 4-door 250 I6
    Just building my little 250 Don :mischeif: !
     
  9. Bluegrass

    Bluegrass Jr. mbr. not really,

    Joined:
    Nov 26, 2003
    Messages:
    515
    Likes Received:
    0
    Trophy Points:
    0
    Location:
    Easton, Pa
    Vehicle:
    73 Comet GT, EFI, C4, Posi
    Unless you have a special application like a blower, there is no need for a return system unless you have certain problems with keeping fuel pressure constant and can't be solved without.
     
  10. boss9

    boss9 Member

    Joined:
    Nov 14, 2005
    Messages:
    569
    Likes Received:
    0
    Trophy Points:
    0
    Location:
    Akron,Ohio
    Vehicle:
    77 4-door 250 I6
    Special application = 58mm TO4 turbo.
    However, I may save myself the additional work and go draw-thru with a 600cfm Holley.
     
  11. MavMark

    MavMark Mega Modifier

    Joined:
    Mar 10, 2002
    Messages:
    779
    Likes Received:
    13
    Trophy Points:
    117
    Location:
    Detroit Area, Michigan
    Vehicle:
    1972 Grabber, 351w,EFI,A/C, RRS Rack, Power Everything :)
    Or...you have EFI. ;)
     
  12. MNTony

    MNTony aka Godzirra

    Joined:
    Jul 8, 2003
    Messages:
    2,026
    Likes Received:
    43
    Trophy Points:
    123
    Location:
    Surprise, AZ
    Vehicle:
    72 Turbo FI Maverick, 2006 GMC Sierra Duramax 4x4, 2014 Ford Mustang GT 4spd
    My vote is for the blow through!
     

Share This Page